DT 45000
|
|
Temperature Transmitter
Sensor Input:
|
Resistors: Pt 100, Pt 200, Pt 500, Pt 1000, Ni 100, Ni 200, Ni 500, Ni 1000;
Thermocouple: B, E, J, K, L, N, R, S, T, U, W5Re_W26Re, W3Re_W25Re;
KTY, resistor, mV and potentiometer measuring
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 mA, 2 to 10 mA
0 to 5 V, 0 to 10 V, 1 to 5 V, 2 to 10 V
|
Measurement Ranges:
|
-270 to +2315 °C, according to sensor type
|
Power Supply:
|
24 V DC
|
Features:
|
Protective Separation, Housing width: 6.2 mm
|
|
|
Details
|
|
DT 45200
|
|
PT Temperature Transmitter
Sensor Input:
|
Pt 100, Pt 200, Pt 500, Pt 1000, Pt 2000 JPt 50, JPt 100
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V
|
Measurement Ranges:
|
-200 to +850 °C, according to sensor type
|
Power Supply:
|
24 V DC
|
Features:
|
Protective Separation, Housing width: 6.2 mm
|
|
|
Details
|
|
DT 45800
|
|
TC Temperature Transmitter
Sensor Input:
|
Thermocouple Type A, B, C, D, E, J, K, L, N, R, S, T, U
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 0 to 10 V
|
Measurement Ranges:
|
-200 to +2500 °C, according to type of thermocouple
|
Power Supply:
|
24 V DC
|
Features:
|
Protective Separation, Housing width: 6.2 mm
|
|
|
Details
|
|
DR 41
|
|
Resistance Transmitter
Sensor input:
|
Fixed ranges within 20 Ohm ... 1 MOhm
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V
|
Power supply:
|
24 V AC/DC
|
Features:
|
Protective Separation, housing width: 11.2 mm
|
|
|
Details
|
|
DR 44
|
|
PT100 4 wire Transmitter
Sensor input:
|
Pt 100, 4-wire connection
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V
|
Ranges:
|
-100 to +450 °C (32 Types)
|
Power supply:
|
24 V AC/DC
|
Features:
|
Protective Separation, housing width: 11.2 mm
|
|
|
Details
|
|
DR 48
|
|
PT100 2 or 3 wire Transmitter
Sensor input:
|
Pt 100, 2- or 3-wire connection
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V
|
Ranges:
|
-100 to +450 °C (32 types)
|
Power supply:
|
24 V AC/DC
|
Features:
|
Protective Separation, housing width: 11.2 mm
|
|
|
Details
|
|
DR 49
|
|
PT1000 2 or 3 wire Transmitter
Sensor input:
|
Pt 100, 2- or 3-wire connection
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V
|
Ranges:
|
-100 to +450 °C (32 types)
|
Power supply:
|
24 V AC/DC
|
Features:
|
Protective Separation, housing width: 11.2 mm
|
|
|
Details
|
|
DR 4310
|
|
Potentiometer Transmitter
Input signal:
|
Potentiometer, 500 Ohm to 100 kOhm
|
Output signal:
|
0 to 20 mA, 4 to 20 mA, ±20 mA, 0 to 10 mA, 2 to 10 mA, ±10 mA
0 to 10 V, 2 to 10 V, ±10 V, 0 to 5 V, 1 to 5 V, ±5V
|
Power supply:
|
20 to 253 V AC/DC
|
Features:
|
Pluggable screw clamp terminals, zero/span compensation,
protective separation, housing width: 12.5 mm
|
|
|
Details
|
|
DR 4700
|
|
PT100, PT1000 Transmitter
Sensor input:
|
Pt 100, Pt 1000
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V
|
Ranges:
|
-100 to +600 °C
|
Power supply:
|
20 to 253 V AC/DC
|
Features:
|
Pluggable screw clamp terminals, sensor diagnostics, protective separation, housing width: 12.5 mm
|
|
|
Details
|
|
DH 11000
|
|
Passive isolator
Input:
|
0(4) to 20 mA
|
1- or 2-channel
|
Output:
|
0(4) to 20 mA
|
Voltage drop:
|
< 2.3 V
|
|
Features:
|
Protective separation, housing width: 6.2 mm
|
|
|
Details
|
|
DH 18
|
|
Passive isolator
Input:
|
0(4) to 20 mA
|
1- and 2-channel versions
|
Output:
|
0(4) to 20 mA
|
Voltage drop:
|
< 3 V
|
|
Features:
|
Protective separation, housing width: 11.2 mm
|
|

|
Details
|
|
DH 1000
|
|
Passive isolator
Input:
|
0(4) to 20 mA
|
1- or 2-channel
|
Output:
|
0(4) to 20 mA
|
Voltage drop:
|
< 2.0 V
|
|
Features:
|
Pluggable screw clamp terminals, protective separation,
housing width: 12.5 mm
|
|
|
Details
|
|
DG 3200
|
|
Alarm Unit
Input:
|
Standard signals 0(4) to 20 mA, ±20 mA, 0 to 10 V, ±10 V (switchable)
|
Output relays:
|
250 V AC/DC, 6 A
|
Power supply:
|
24 V AC/DC
|
Features:
|
Relay with high power handling, protective separation,
housing width: 22.5 mm
|
|
|
Details
|
|
DG 3300
|
|
Current Measuring Contactor
Input:
|
0 to 1 A, ±1 A, 0 to 5 A, ±5 A (switchable)
|
Output relays:
|
250 V AC/DC, 6 A
|
Power supply:
|
24 V AC/DC
|
Features:
|
Relay with high power handling, protective separation,
housing width: 22.5 mm
|
|
|
Details |
|
DG 3400
|
|
Voltage Measuring Contactor
Input:
|
24 V, 48 V, 100 V, 120 V, 250 V, 500 V (switchable)
|
Output relays:
|
250 V AC/DC, 6 A
|
Power supply:
|
24 V AC/DC
|
Features:
|
Relay with high power handling, protective separation,
housing width: 22.5 mm
|
|
|
Details |
|
DG 3600
|
|
Temperature Alarm Unit
Sensor input:
|
Pt100, Pt200, Pt500, Pt1000 (switchable)
|
Output relays:
|
250 V AC/DC, 6 A
|
Power supply:
|
24 V AC/DC
|
Features:
|
Relay with high power handling, protective separation,
housing width: 22.5 mm
|
|
|
Details |
|
DC 58
|
|
Passive Transmitter Repeater
Input:
|
4 to 20 mA
|
Output:
|
4 to 20 mA
|
Voltage drop:
|
Approx. 4.7 V
|
Features:
|
Protective separation, housing width: 11.2 mm
|
|
|
Details |
|
DC 52100
|
|
Powered Repeater
Input:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, calibrated switchable
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, calibrated switchable
|
Power supply:
|
24 V DC
|
Features:
|
Protective separation, housing width: 6.2 mm
|
|
|
Details |
|
DC 52500
|
|
Powered HART Repeater
Input:
|
0/4 to 20 mA
|
Energization of 2-wire transmitters
|
Output:
|
0/4 to 20 mA
|
Bidirectional HART communication
|
Power supply:
|
24 V DC
|
|
Features:
|
Protective separation, housing width: 6.2 mm
|
|
|
Details |
|
DN 25000
|
|
Isolation Amplifier
Input:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, calibrated switchable
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, calibrated switchable
|
Power supply:
|
24 V DC
|
Features:
|
Calibrated signal setting, protective separation, housing width: 6.2 mm
|
|
|
Details |
|
DN 28
|
|
Isolation Amplifier
Input:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V
|
Power supply:
|
24 V AC/DC
|
Features:
|
Protective separation, housing width: 11.2 mm
|
|
|
Details |
|
DN 2000
|
|
Isolation Amplifier
Input:
|
0...20 mA, 4...20 mA, 0...10 V
|
Output:
|
0...20 mA, 4...20 mA, 0...10 V
|
Power supply:
|
20 ... 253 V AC/DC
|
Features:
|
Pluggable screw clamp terminals, calibrated signal setting,
protective separation, housing width: 12.5 mm
|
|
|
Details |
|
DN 2300
|
|
Isolation Amplifier
Input:
|
0(4) to 20 mA
|
Output:
|
0(4) to 20 mA
|
Power supply:
|
20 to 253 V AC/DC
|
Features:
|
Pluggable screw clamp terminals, zero/span compensation,
protective separation, housing width: 12.5 mm
|
|
|
Details |
|
DN 2400
|
|
Isolation Amplifier
Input:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V
|
Power supply:
|
20 to 253 V AC/DC
|
Features:
|
Pluggable screw clamp terminals, calibrated signal setting,
housing width: 12.5 mm
|
|
|
Details |
|
DN 240M
|
|
Isolation Amplifier Module
Input:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V terminal selectable
|
Output:
|
0 to 20 mA, 4 to 20 mA, 0 to 10 V terminal selectable
|
Power supply:
|
24 V DC
|
Features:
|
solder-in module, Calibrated signal setting, 3-port isolation,
flat module housing for PCB assembling
|
|

|
Details |
|
DN 21000
|
|
Signal Splitter
Input:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V
|
Output 1:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V
|
Output 2:
|
0 to 20 mA, 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V
|
Power supply:
|
24 V DC
|
Features:
|
Calibrated signal setting, protective separation,
housing width: 6.2 mm
|
|
|
Details |
|
|