Hazardous Area Ex d, Ex e, Ex tD

TCA Hazardous Area Sensors IECEx Certification

Ex ia Intrinsically Safe Applications
Ex d Flame proof Applications
Ex e Increased Safety Applications
Ex tD Protection by Enclosure for Dust

Temperature Controls Pty Ltd are able to offer temperature assemblies suitable for use in the above environments. The use of any electrical apparatus in these areas is strictly controlled by using the above protection techniques.

Temperature Controls Pty Ltd have obtained IECEx approval for thermocouple and RTD Assemblies, suitable for use in flameproof and increased safety classified installations.

The certification covers the terminal head and temperature element providing IECEx approval for the complete assembly.

Terminal heads or temperature elements (Thermocouples / RTD sensors) may be supplied as components to suit your application.

IEC Ex Certification 
IEC 60079.1:2001 Ex d Part 1 Flame proof Enclosures “d” 
IEC 60079.7:2001 Ex e Part 7 Increased Safety “e”
IEC 61241 - 1:2004 Electrical Apparatus for use in the Presence of Combustible Dust.

To obtain our detailed 4 page Hazardous area literature and certificate of conformance, please click: SD 1357

Technical Information

Guide to all IECEx drawings & data sheets

Drawing No. Certificate No. Installation Instructions Model No.
SD 558 (Ex d Flameproof) IECEx TSA 06.0007U (1367) 1378 TC20EXD1
SD 558 (Ex e Increased Safety) IECEx TSA 06.0007U (1367) 1379 TC20EXE1
SD 575 – NUN SL IECEx TSA 09.0045X (1369) 1375 TC20SPRTA/Ex d
SD 572 - SL IECEx TSA 09.0045X (1369) 1375 TC20SPRTA/Ex d
SD 589 - LAG SL IECEx TSA 09.0045X (1369) 1375 TC20SPRTA/Ex d
SD 599 - LAG FIXED IECEx TSA 09.0045X (1369) 1375 TC20SPRTA/Ex d
SD 569 - FIXED IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex d
SD 619 - FIXED IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex d
SD 574 – NUN SL IECEx TSA 09.0045X (1369) 1375 TC20SPRTA/Ex e
SD 573 - SL IECEx TSA 09.0045X (1369) 1375 TC20SPRTA/Ex e
SD 568 - FIXED IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex e
SD 576 – NUN SL IECEx TSA 09.0044U (1368) 1376 TCSPREX
SD 571 -SL IECEx TSA 09.0044U (1368) 1376 TCSPREX
SD 638 -LAG SL IECEx TSA 09.0044U (1368) 1376 TCSPREX
SD 570 - FIXED IECEx TSA 09.0044U (1368) 1380 TCFIXEX
SD 601 -LAG FIXED IECEx TSA 09.0044U (1368) 1380 TCSPREX
SD 580 - WM-PAD IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex d
SD 581 -WM-PAD IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex e
SD 625 90º SKIN TUBE IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex d
SD 624 180º SKIN TUBE IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex d
SD 582 - WM-AIR IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex d
SD 583 - WM-AIR IECEx TSA 09.0045X (1369) 1377 TC20FIXTA/Ex e
 
SD 1372 All IECEx drawings
SD 578 (6682) Lagging extension options    
07-32 IECEx Register   In SAP

Other Hazardous Area products

IECEx TSA 06.0007U Liquid level switch SD 523
Baseefa03ATEX0347X Stainless steel compression fitting M20/6mm (Ex d ) 1258
Ex ia Technical information RE: Equipment for Hazardous areas 1047
SD 050 Ex ia MIMS thermocouple basic assembly drawing SD 050 Ex ia

Inor Head mounted Transmitters ( Ex ia )

MODEL INPUT ISOLATED COMMS Ex ia ATEX Ex ia Certificate MOUNTING DATA SHEET
APAQ-HRFX RTD NON NO YES SD 1145 HEAD SD 1118
APAQ-HCFX J,K,T,N NON NO YES SD 1145 HEAD SD 1118
IPAQ-HX MULTI ISOLATED NO YES SD 1146 HEAD SD 1078
MESO-HX MULTI ISOLATED HART YES SD 1147 HEAD SD 1071

 

Level

Level Switches (Reed switches) (SD 1047)
Our Level Switches (Reed switches) when fitted with 600 V Rated wiring are simple apparatus and with appropriate barriers can be installed freely in IS circuits, (Ex ia) no further certification is required.

SD 558

Rev: 01  Date: 15/2/10

Size: 47.26 KB

SD 575

Rev: 02  Date: 21/05/08

Size: 116.62 KB

SD 572

Rev: 02  Date: 23/05/08

Size: 107.21 KB

SD 589

Rev: 03  Date: 22/05/08

Size: 110.83 KB

SD 599

Rev: 03  Date: 22/05/08

Size: 95.42 KB

SD 729

Rev: 01  Date: 24/6/09

Size: 97.53 KB

SD 569

Rev: 03  Date: 8/10/08

Size: 97.29 KB

SD 619

Rev: 01  Date: 21.05.08

Size: 108.00 KB

SD 574

Rev: 01  Date: 22/05/08

Size: 90.60 KB

SD 573

Rev: 01  Date: 22/05/0

Size: 101.32 KB

SD 568

Rev: 04  Date: 15/02/10

Size: 89.28 KB

SD 576

Rev: 03  Date: 18/12/07

Size: 88.10 KB

SD 571

Rev: 04  Date: 22.04.09

Size: 113.05 KB

SD 638

Rev: 02  Date: 17/02/10

Size: 116.54 KB

SD 570

Rev: 05  Date: 14/9/09

Size: 103.82 KB

SD 601

Rev: 03  Date: 18/02/10

Size: 102.43 KB

SD 580

Rev: 01  Date: 22/05/08

Size: 68.06 KB

SD 581

Rev: 01  Date: 22/05/08

Size: 69.81 KB

SD 625

Rev: 04  Date: 17/02/10

Size: 109.02 KB

SD 624

Rev: 03  Date: 17/02/10

Size: 109.67 KB

SD 582

Rev: 02  Date: 23/05/08

Size: 67.55 KB

SD 583

Rev: 01  Date: 22/05/08

Size: 69.39 KB

Do you know ?

Ex d Flameproof Protection

All electrical connections and equipment are enclosed in a housing strong enough to contain any explosion or fire that may take place inside the housing.

Ex e Increased Safety

All electrical connections and equipment incorporate special measures to reduce the probability of excessive temperatures and the occurrence of arcs and sparks in normal service.

Ex ia Intrinsically Safety

The electrical energy available in circuits and equipment, is limited to a level too low to ignite the most easily ignitable mixtures in a hazardous area. Intrinsically safe barriers, Zener or Transformer Isolated, are installed in the circuit to limit current and voltage in the hazardous area to prevent sparking under fault conditions.